Candle KLVHSKONCT GC32-9172-00 User Manual Page 105

  • Download
  • Add to my manuals
  • Print
  • Page
    / 522
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 104
KLVSD001KLXOP005 105
KLVTB012 UNABLE TO LOAD TABLE CLUSTER: DSNAME(dsname) R15(value)
RPLERRCD(value) DCR(hex)
Explanation: CT/Engine tables initialization could not format the tables
database because the VSAM PUT macro failed.
System Action: CT/Engine initialization is terminated.
User Response: Retain the CT/Engine run sheets and dump files, this message,
and the MVS system log, then contact Candle Customer Support.
Message Type: ERROR.
KLVTB013 GENCB MACRO FAILURE R15(value) R0(value)
Explanation: CT/Engine tables initialization could not format the tables
database because the VSAM GENCB macro failed.
System Action: CT/Engine initialization is terminated.
User Response: Retain the CT/Engine run sheets and dump files, this message,
and the MVS system log, then contact Candle Customer Support.
Message Type: ERROR.
KLVTB014 INVALID KEY LENGTH IN TABLE DATABASE: SUPPLIED(actual)
EXPECTED(valid)
Explanation: The CT/Engine tables database is incorrectly allocated. valid is the
required VSAM cluster key length; actual is the key length found on the actual
cluster.
System Action: CT/Engine initialization is terminated.
User Response: Reallocate the tables database cluster with the proper key and
control interval sizes, then restart CT/Engine.
Message Type: ERROR.
KLVTB015 INVALID RECORD LENGTH IN TABLE DATABASE: SUPPLIED(actual)
EXPECTED(valid)
Explanation: The CT/Engine tables database is incorrectly allocated. valid is the
minimum VSAM cluster record length; actual is the record length found on the
cluster.
System Action: CT/Engine initialization is terminated.
User Response: Reallocate the tables database cluster with the proper key and
control interval sizes, then restart CT/Engine.
Message Type: ERROR.
KLVTB016 NO TABLE DATABASE SPECIFIED - PERMANENT TABLES NOT
SUPPORTED
Explanation: The CT/Engine initialization member (KLVINTB in RKANPAR) is
either not present or is empty.
System Action: CT/Engine initialization continues, but no permanent table
services are available. These include TBOPEN, TBSAVE, and TBLIST. Attempts
to use these will result in return codes of 8, 12 and/or 20 from the associated
functions.
Page view 104